Serial call-expansion board for the controller, adding cabin calls or landing inputs/outputs on the Movilift CANbus.
- CANbus
- Expansion

- Inputs
- 12
- Outputs
- 12
Overview
The CHM expands the controller's calls over the Movilift CANbus. Inputs and outputs adapt to the lift manoeuvre type, with node addressing set by two dip-switches.
- 12 GND call inputs and 12 GND call outputs
- Two dip-switches for CAN node programming
- Diagnostic LED
Specifications
| Usage | In the controller |
|---|---|
| Serial communication | CANbus (Movilift) |
| Inputs | 12 GND calls |
| Outputs | 12 GND calls |
| Programming | Two dip-switches (CAN node) |
| Dimensions | 140 x 50 mm |
| Power supply | 12–24 VDC ±10% |
| Maximum overvoltage | 30 V |
| Current consumption | 150 mA typ. |
| Operating temperature | -20 °C to +60 °C |
| Storage temperature | -25 °C to +60 °C |
| Managed floors | Up to 24, with up to 4 boards in parallel |