Skip to main content

CHM

Serial call-expansion board for the controller, adding cabin calls or landing inputs/outputs on the Movilift CANbus.

Manuals
  • CANbus
  • Expansion
CHM — Movilift
Inputs
12
Outputs
12

Overview

The CHM expands the controller's calls over the Movilift CANbus. Inputs and outputs adapt to the lift manoeuvre type, with node addressing set by two dip-switches.

  • 12 GND call inputs and 12 GND call outputs
  • Two dip-switches for CAN node programming
  • Diagnostic LED

Specifications

UsageIn the controller
Serial communicationCANbus (Movilift)
Inputs12 GND calls
Outputs12 GND calls
ProgrammingTwo dip-switches (CAN node)
Dimensions140 x 50 mm
Power supply12–24 VDC ±10%
Maximum overvoltage30 V
Current consumption150 mA typ.
Operating temperature-20 °C to +60 °C
Storage temperature-25 °C to +60 °C
Managed floorsUp to 24, with up to 4 boards in parallel

Compatibility

  • MoviLift serial (CAN)